● General Description:
FOCC's Small Form Factor Pluggable (SFP) transceivers are compatible with the dimensions defined by the SFP Multi-Sourcing Agreement (MSA). FOCC is in the business of network innovation. From devices to data centers, from consumers to cloud providers, FOCC delivers the software, silicon and systems that transform the experience and economics of networking. The company serves customers and partners worldwide.
● Quick Details:
► The following table lists the different pluggable optic modules and supported platforms, along
with the technical specifications for each;
► SFP (mini-GBIC) transceiver module.
● Application:
► 10GBASE-LR at 10.3125Gbps;
► 10GBASE-LW at 9.953Gbps;
► Other optical links.
● Block Diagram:
● Description:
Form Factor | Plug-in module |
Compatibility |
Cisco Compatible |
Distance |
20km |
Max Data Rate |
1000Mbps |
Wavelength |
1310 (RX) / 1490 (TX) nm |
Connectivity Technology |
Wired |
Interface |
LC Duplex |
Type |
SFP (mini-GBIC) transceiver module |
DOM Support |
Yes |
Cable Type |
SMF |
TX Power |
-9.5 ~ - 3dBm |
Receiver Sensitivity |
< -17dBm |
HS Code |
Optical fibre cables-85447000.00 |
● Optical characteristics transceiver:
Parameters | Symbols |
Min |
Typ |
Max |
Unit |
40km | |||||
Centre Wavelength BXD |
λC |
1320 |
1330 |
1340 |
nm |
Centre Wavelength BXU |
λC |
1260 |
1270 |
1280 |
nm |
Spectral Width (RMS) |
σ |
|
|
1 |
nm |
Average Output Power |
P0ut |
-3 |
|
+2 |
dBm |
Extinction Ratio |
EX |
3.5 |
6 |
|
dB |
● Mechanical Specifications:
● Optical characteristics receiver:
Parameters | Symbols |
Min |
Typ |
Max |
Unit |
20km | |||||
Centre Wavelength BXD |
λC |
1260 |
1270 |
1280 |
nm |
Centre Wavelength BXU |
λC |
1320 |
1330 |
1340 |
nm |
Reveiver Sensitivity |
Sen |
-14.5 |
|
|
dBm |
Maximum input |
Pmax |
0 |
|
|
dBm |
LOS De-Assert |
LOSd |
|
|
-14 |
dBm |
LOS Assert |
LOSa |
-25 |
|
|
dBm |
LOS Hysteresis |
LOSh |
0.5 |
|
4 |
dBm |
40km | |||||
Centre Wavelength BXD |
λC |
1260 |
1270 |
1280 |
nm |
Centre Wavelength BXU |
λC |
1320 |
1330 |
1340 |
nm |
Reveiver Sensitivity |
Sen |
-16 |
|
|
dBm |
Maximum input |
Pmax |
0 |
|
|
dBm |
LOS De-Assert |
LOSd |
|
|
-17 |
dBm |
LOS Assert |
LOSa |
-27 |
|
|
dBm |
LOS Hysteresis |
LOSh |
0.5 |
|
4 |
dBm |
60km | |||||
Centre Wavelength BXD |
λC |
1260 |
1270 |
1280 |
nm |
Centre Wavelength BXU |
λC |
1320 |
1330 |
1340 |
nm |
Reveiver Sensitivity |
Sen |
-22 |
|
|
dBm |
Maximum input |
Pmax |
-7 |
|
|
dBm |
LOS De-Assert |
LOSd |
|
|
-23 |
dBm |
LOS Assert |
LOSa |
-33 |
|
|
dBm |
LOS Hysteresis |
LOSh |
0.5 |
|
4 |
dBm |
80km | |||||
Centre Wavelength BXD |
λC |
1480 |
1490 |
1500 |
nm |
Centre Wavelength BXU |
λC |
1530 |
1570 |
1580 |
nm |
Reveiver Sensitivity |
Sen |
-22 |
|
-7 |
dBm |
Maximum input |
Pmax |
-7 |
|
|
dBm |
LOS De-Assert |
LOSd |
|
|
-24 |
dBm |
LOS Assert |
LOSa |
-34 |
|
|
dBm |
LOS Hysteresis |
LOSh |
0.5 |
|
|
dBm |
Dispersion penalty |
|
|
|
3.0 |
dBm |
● Electrical characteristics:
Parameters | Symbols |
Min |
Typ |
Max |
Unit |
Remarks |
Supply Voltage |
Vcc |
3.14 |
3.3 |
3.46 |
V |
|
Supply Current 20km |
Icc |
|
270 |
350 |
mA |
|
Supply Current 40km |
|
|
300 |
450 |
mA |
|
Supply Current 60km |
|
|
300 |
450 |
mA |
|
Supply Current 80km |
|
|
|
500 |
mA |
|
| ||||||
Supply Voltage |
Vcc |
3.14 |
3.3 |
3.46 |
V |
|
Supply Current |
Icc |
|
|
300 |
mA |
|
Reference Differential Input |
Zd |
|
100 |
|
mA |
|
Input AC Common Mode Input |
|
0 |
25 |
|
mA |
|
Differential Input Voltage Swing |
VID |
150 |
|
900 |
mA |
|
Total Jitter |
|
|
|
|
|
|
Data Dependant Jitter |
|
|
|
|
|
|
Uncorrelated Jitter |
|
|
|
|
|
|
Eye Mask |
See SFP+ MSA |
X1 |
|
|
|
UI |
Eye Mask |
See SFP+ MSA |
X2 |
|
|
0.35 |
UI |
● About FOCC Company:
FOCC Optical transceivers are built to meet or exceed the OEM's specifications, and comply with MSA (Multi-Source Agreement) standards. All products are 100% functionally tested, and are guaranteed compatible. FOCC's industry-standard SFP is a hot-swappable input/output device that plugs into a Gigabit Ethernet slot, linking the port with the fiber-optic network. Proline transceivers (GBIC, SFP, SFP+, X2, XFP and XENPAK) are 100% compliant for all networking product lines, and are factory loaded with OEM specific configuration data required for networking compliance. These transceivers initialize and perform identically to the OEM transceivers and can be mixed and deployed with other OEM or 3rd party transceivers, for seamless network performance. FOCC-BX-U-CDW is a Cisco compatible SFP module with the following features: 1000BASE-BX80-U, TX-1490nm/RX-1550nm or TX-1510nm/RX-1570nm Wavelengths, LC Connector, Single-mode Fiber (SMF), up to 80km reach (Distance), Upstream Bidirectional.